Web Diagnosis: Login dialogue

Function extension:
The Lenze controllers have a web server. By entering the IP address of the controller in an Internet browser, a diagnostic page (Web Diagnostic) can be opened.

With the current firmware version of the controller, a login dialogue opens after calling up the Web Diagnosis. 
By default, two users with different rights are created in the controller:
  • User 'guest'
    Name: guest
    Password: guest
    Rights: 
    • Change password
    • Perform a global reset of pending error messages.
  • User 'advanced':
    Name: advanced
    Password: default
    Rights in addition to user 'guest':
    • Edit user
    • Add user
    • Set up an uncomplicated call-up of the web Diagnosis without password entry and thus waive the security function, by creating the
      Users: 'autologin'
      Password:'autologin'
    • Remove user
    • Delete controller logbook
The password of the standard user must be changed the first time it is used.

Contained in which products?
Cabinet Controller c520 from V1.9
Cabinet Controller c550 from V1.9

Application:
Display of diagnostic information on the Lenze controller (logbook, licence manager,...).


Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200250/1/