Object 'ParameterEditor'

Function extension:
The 'ParameterEditor' object is located in the device tree of the PLC Designer project. The Parameter Editor supports the creation and editing of application-specific parameters. The parameter editor is used to
  • establish a link between a variable from a user data type or function block to a parameter, and
  • define the behaviour and the view of the parameter (display texts, scaling, input limits,...) 
Contained in which products?
Cabinet Controller c300 V3.21
Cabinet Controller 3200C V3.21
Cabinet Controller c520 V1.7
Cabinet Controller c550 V1.7
Cabinet Controller c750 V1.7
Panel Controller p300 V3.21
Panel Controller p500 V3.21
Servo Umrichter i950 V1.7.4

Application:
The parameter set of the Lenze controllers and the i950 servo inverter can be extended by user parameters. This makes it possible to influence PLC program processing without having to change and re-download the PLC program. In addition, user parameters can display application-specific actual values or diagnostic information.

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202100346/1/
Kontaktformular