i950 Logbook: Export file sometimes does not contain all existing entries (corrected from V01.06.04)

Corrected from:
Servo Inverter i950 FW: from V01.06.04.2154
 
Response of the new version:
When exporting the logbook, the following entries are now also read out if there is an empty line. The empty line is simply skipped. In the exported logbook file such a case can be recognised by the fact that the corresponding number is missing in the list.


What happens?
The logbook cannot be exported completely and only up to a certain point. Subsequent entries are not contained in the exported logbook file. 
The reason for this behaviour is a blank line in the logbook. This blank line has the effect that when the logbook is exported, the reading of the logbook is stopped at this point and it looks in the logbook analysis as if no further entries have been made. In fact, however, further events may have been correctly written into the logbook.
Unfortunately, the reason for the entry of an empty row in the logbook could not be found out so far.

Which products are affected?
Servo-Inverter i950 FW
 
Short-term measures / evaluation / recommendations:
Delete the logbook and start with an empty logbook that does not contain any gaps/blank lines.
When exporting the logbook, all entries will be written to the export file again.

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202100218/1/
Kontaktformular