No access to a "REFERENCE TO" variable

What happens?
The variable cannot be read via OPC-UA or the variable cannot be used in VisiWinNET (driver LogicAndMotionV3).
The error messages "BadNodeIdInvalid", "Publish failed" and "BadNodeIdUnknown" appear.
 
When does the behaviour occur?
There is another structure within a structure.
The inner structure is declared with "REFRENCE TO" in the outer structure.
Example:
Reference_to_struct.png 

Which products are affected?

Controller 3200C

Controller p500

Controller c300

Controller p300

Short-term measures:

Do not use "REFERENCE TO" constructs if you want to access these variables with a visualization via OPC-UA or the LogicAndMotionV3 driver.

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000100/1/