TTL encoder: Support of new encoder modules with TTL evaluation (from V01.04.01)

Function extension:
TTL encoder:  The evaluation of TTL encoders with a cut-off frequency of up to 500 kHz is now possible.
For this purpose the encoder selection has been extended by the selection 3: TTL encoder:
  • 0x2C40 Motor encoder type
  • 0x2C50 Load encoder/master encoder type
The current hardware of the encoder modules is required.
Identification of encoder modules for TTL encoders

Contained in which products?
Servo inverter i950 FW:  from V01.04.01.1471

Application:
Evaluation of motor encoders and master value encoders with TTL signals. The encoder input can therefore also be used as a master frequency input as with 9400, 8400 TL. The i950 does not support functionality as a master frequency output.
 
Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000061/1/