i950 TA Winder: Homing request during JogLine does not generate warning (corrected from V03.20.00)

Corrected from:
Library:   (FAST Motion Modules V2) L_TW2P_TechModulesWindingTraversing:  from V03.20.00.33
(Update via EASY Package Manager)
 
Response of the new version:
It will issue a warning if a referencing (xHomeExecute = TRUE) should be requested during the active LineJogging function (xJogLinePos = TRUE).
 
 
What happens?
No warning is issued during referencing.
 
When does the behaviour occur?
Servo-Umrichter i950 with TA Winder: A referencing (xHomeExecute = TRUE) is executed during LinePos (xJogLinePos = TRUE).
Using function blocks L_TW2P_WinderDancerCtrlState or L_TW2P_WinderTensionrCtrlState.
 
Which products are affected:
Library:   (FAST Motion Modules V2) L_TW2P_TechModulesWindingTraversing
 
Short-term measures, Evaluation / Recommendations:
During the LineJogging (xJoggingBusy = TRUE) function, no referencing (xHomeExecute = TRUE) should be ordered
No function is impaired by the inadmissible control of referencing with xHomeExecute = TRUE.
 
Automatic Translation