The 'SRelease.inf' file cannot be directly created after starting the inverter (corrected from base FW V01.02.03)

​Corrected from:
i950 servo inverter from base firmware V01.02.03.985

Response of the new version:
The 'SRelease.inf' file can now always be directly created after starting the inverter.

 
What happens?
The 'SRelease.inf' file cannot be created after starting the inverter.
 
When does this behaviour occur?
The behaviour occurs if the SD card does not yet contain a file with the same name ('SRelease.inf') and
the time elapsed after starting the inverter is not at least 60 seconds.
 
Which products are affected?
i950 servo inverter within Extended safety V01.01.03

Short-term measures:
After switching on/starting the inverter, wait at least 60 seconds before creating the 'SRelease.inf' file.
 
Evaluation/recommendations:
Useability issue. Remedy see short-term measure.
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800279/1/