Additional ramp times

Function extension:
New: There is an additional acceleration and deceleration time available. The additional ramp times are set in C00101/1 (Add. acceleration time 1) and C00103/3 (Add. deceleration time 1). They are activated via the application input C00701/37.
Contained in which products?

  • Inverter Drives 8400 motec;

Application:

  • Optimisation of the SLPSM motor control. Flat ramps for acceleration and deceleration in open-loop controlled operation and steep ramps in closed-loop controlled operation lead to a much higher acceleration of the entire drive and there are less oscillations. The additional ramp times are activated via C00701/37 selection 90.
  • Use as additional ramp time

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800021/1/