Motor control: Output frequency has been limited to max. 599 Hz (from V1.9.3)

Function extension:
The maximum output frequency of the i700 servo inverters has been limited to ± 599 Hz.
Devices with the previous maximum output frequency of ± 1999 Hz continue to be available with restrictions, see below.
 
Contained in which products?
- i700 servo inverter  from V01.09.03.10964 
- applies to all devices supplied as of the middle of 2015.
 
Application: 
For special applications requiring higher output frequencies, devices with the previous maximum output frequency of ± 1999 Hz can be delivered subject to compliance with certain conditions. If required, please contact your local Lenze sales representatives.
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201600019/1/