Corrected from:
- Inverter Drives 8400 protec HighLine V08.01.00 0.37 kW - 5.5 kW
- Inverter Drives 8400 protec HighLine V16.01.00 7.5 kW
Response of the new version:
From the new version onwards, an SSI-encoder overflow will be included in the "LS_MultiEncoder: Max. position jump" monitoring function and no error will be tripped.
What happens?
When the max. position jump monitoring function is active, the "LS_MultiEncoder: bFail" output bit is not set correctly.
When does this behaviour occur?
The behaviour occurs when using a rotary SSI encoder and overtravelling the value range (overflow of the position read by the SSI encoder). Activation of code C1112:4.
Which products are affected?
- Inverter Drives 8400 protec HighLine lower than V08.01.00 0.37 kW - 5.5 kW
- Inverter Drives 8400 protec HighLine lower than V16.01.00 7.5 kW
Short-term measures:
-
Evaluation/recommendations:
-