SLVC: OC1/OC11 error if fd>650Hz

Corrected from:
Inverter Drives 8400 StateLine, HighLine, and TopLine from firmware version 14.00.00.00

Response of the new version?
SLVC: Motors with fd > 650 Hz (up to 1000 Hz) are now supported.

Which products are affected?
Inverter Drives 8400 StateLine, HighLine, and TopLine with a firmware version lower than 14.00.00.00

What happens?
Disconnection of the frequency inverter with OC1/OC11.

When does the problem occur?
SLVC control mode does not work if fd > 650Hz (OC1/OC11 when 650Hz are reached)

Short-term measures/recommendations?
None

Evaluation:
A motor with a base frequency fd> 650 Hz cannot be commissioned in SLVC control mode with FW< 14.00.00.00.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500657/1/