SSI encoder evaluation, extension of the number of status bits to 3

Which products are affected?

Inverter Drives 8400 TopLine from firmware version 14.00.00.00

Functional description

The number of evaluable status bits for the SSI encoder has been extended to 3 bits. In codes C426/8+9, the bit to be evaluated is defined in the SSI data stream.

If the evaluation of a status bit is to be completely deactivated, the value "32" is to be entered in the corresponding code. Like this, the status bit always has the value "0"


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500636/1/
Kontaktformular