Increase of the maximum current limit at a fixed switching frequency of 4kHz for a power of 30kW, 37kW, and 45kW
Which products are affected?
Inverter Drives 8400 StateLine, HighLine, and TopLine from firmware version 14.00.00.00
Functional description
For a fixed switching frequency and fch=4kHz and fd>3Hz, the maximum current thresholds for 30kW, 37kW, and 45kW have been increased by 15%. This makes it possible for the inverter to build up a higher torque (current).