- Version history VisiWinNET® 6.5.3

The following explanations describe the new functions of VisiWinNET® version 6.5 SP3, which function restrictions have been corrected, and known function restrictions and possible remedies.
 
Function extensions:
- p300 HMI and p300 PLC have been added to the device catalogue.
- p300 4.3": Special Lenze templates for FCentral(Home), recipe system, alarm system, user management, Common have been added.
 
Eliminated function restrictions:
SMART integrated development environment:
- Only the external variables are still considered for the target-device-dependent restriction of the maxium number of definable variables.
- For Container Controls (e.g. GroupBox), SuspentLayout and ResumeLayout is now also called in SmartForms.
- Loading of different .NET assemblies failed when starting Smart Compact CE projects on devices with Compact Framework 3.5 and led to missleading error messages in the log file.
- Drivers with driver core version higher than 1.0.0.0 could not be loaded in the emulator.
 
Control elements:
- Move: Under Windows CE, the image was not shown.
- Command button: A 2-pixel offset was missing with ButtonStyle=Graphical and TextAlign=TopLeft.
- TouchKeyboard templates under Windows CE: When pressing another key when deactivating the touch keyboard, the system froze.
- ListView: If the last column was made invisible, the header was not drawn correctly.
- ListView: For the "LocalizedText" column type, the change events of the texts were not evaluated.
- TrendCurve: When programmatically copying curves, the scale was not initialised correctly.
- TrendChart: With logarithmic representation, zooming was not correct and the marker calculated incorrect values.
- Bar: SmartTag dialog for scale did not work.
 
Compact runtime system:
- Alarm management: File limitation of the historic alarm archives blocked the application if the maximum number of archive files was reached.
- Recipe system: Due to a modification in SP2, recipes with structure variables could no longer be transferred to the controller or be read by the controller.
- Recipe system: Reading recipes with variables from deactivated channels led to an exception error.
- Logging: Part of the LogFile dialog was not shown correctly.
 
Standard runtime system:
- Language selection: For new projects, more than 8 languages can now be defined (so far, only 8 languages could be defined).
- Logging: With the new "Do not record initial variable values" option, you can now define that initial variable values are not be recorded when starting the system.
- Client configuration: The "Timeout with existing connection" option was not observed.
 
Known functional restrictions:
- LogicAndMotionV3 Driver: no support for online users
 
Compatibility with earlier versions:
Downwards compatible in terms of functions.
Higher software versions support all functions of the previous software versions.

Due to an error correction of the anchor feature of the VisiWin control elements, the control elements may not be shown correctly at runtime.
If the anchor feature was set to a value other than the standard value (left, top) for a control element,
the form must be altered once and saved again. For this purpose, place any control element onto
the corresponding form, delete it again and save the form.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400177/1/