Hiperface® absolute value encoders SEK37, SEL37, SEK52, SEL52 evaluable

Which products are affected?
9400 HighLine from firmware version 11.00.10.00
9400 Servo PLC from firmware version 05.00.10.00
 
Functional description
In C412 Hiperface: initialisation time, the initialisation time of C412=1200ms required for these encoders can be parameterised. The Lenze setting is C412=650ms according to the original Sick Hiperface® specification.
For further encoders with a prolonged initialisation time, the initialisation time required in each case can be gathered from the associated absolute value encoder data sheet. 
 
Applications
A Hiperface® encoder with an initialisation time deviating from the Hiperface® specification is to be used on the controller. This affects for instance the absolute value encoders of the SEK37, SEL37, SEK52, and SEL52 type by the company Sick. ​