8400 StateLine, HighLine and TopLine: FW version = 13.00.00.00
Response of the new version?
If an Id4 error occurs during the extended motor parameter identification, 'Action aborted' is reported via C002.
Which products are affected?
8400 StateLine, HighLine and TopLine: FW version ≤ 13.00.00.00
What happens?
If an Id4 error occurs during the extended motor parameter identification, 'Off/completed' is reported via C002.
When does the problem occur?
Every time an Id4 error (resistor identification error) occurs during the extended motor parameter identification. This is for instance the case if the parameterisation of the motor cable length is incorrect.
Diagnostics options?
Read out C002.
Short-term measures/recommendations?
None.
Evaluation:
The C002 'Off/completed' status indicates that the identification has been carried out successfully although it was aborted with an error message. Only if solely the C002 status is evaluated and the error message is disregarded, the motor parameters that are 'not identified' can have an impact on the motor control. This is only of very minor practical relevance.