Logbook read interface for the control or HMI

Which products are affected?
Inverter Drives 8400 StateLine, HighLine, and TopLine from firmware version 12.00.00.00

Functional description
Via a write request on C191/1, reading of a logbook line can be requested.
The contents of the logbook line addressed is then provided on two parameter interfaces:
• As 'octet string' (string consisting of 8 double words) in C192/1 which has to be decoded in the control/HMI.
• Or as single information in C193/1-6 that has already been decoded.
(index, activity flag, error counter, error type, error subject area+ID, and time)

Applications
Reading out of logbook contents via SDO communication by a control or an HMI parallel to the Engineer and/or Easy Starter.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201300900/1/