Incorrect conversion into application units of the LS_DisFree_a

Which products are affected?
StateLine with firmware version V11.00

What happens?
The display of internal process factors and their conversion into application units with the 'LS_DisFree_a' system block does not yield any values. The display value in codes C00487/1 - 4 remains unchanged.

When does the problem occur?
If inverter-internal process factors are to be displayed on the keypad via codes C00487/1 - 4.

Diagnostics options?
The signal levels in codes C00487/1 - 4 always display a value of '0'.

Short-term measures/recommendations?
The input signal (without conversion into application units) is displayed in codes C00482/1-4.

Evaluation:
These parameters are just display values which do not affect the drive behaviour.