Display of Lenze code C13879 or C14879 (bus error)

Corrected from:
EtherCAT E94AYCET Firmware Version 3.00 communication module

Behaviour of the new version?
In the fault-free state of EtherCAT communication, the Lenze code C13879 or C14879 (bus error) indicates the value '0x00000000', and in the faulty state it indicates the value '0x00000001'.



What happens?
In the fault-free state of EtherCAT communication, the Lenze code C13879 or C14879 sporadically indicates the value '0x01000000', and in the faulty state it sporadically indicates the value '0x01001001'.

When does the problem occur?
The representation of code C13879 or C14879 always is incorrect.

Which products are affected?
EtherCAT E94AYCET FV 2.0 communication module
EtherCAT E94AYCET FV 1.01 communication module

Diagnostics options?
When reading out code C13879 or C14879, bit 24 is set.

Short-term measures/recommendations?
None

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201204242/1/