QSP with position control (8400 HighLine from V10.0, TopLine from V01.10)

Function extension:
So far, the QSP function has been executed without position control. Starting with the above-mentioned firmware, the position control can be activated via code C0104. Two options are provided:
  • Activation of the position control from standstill
  • Activation of the position control along the QSP deceleration ramp

Which products are concerned?
8400 HighLine with firmware from V10.00
8400 TopLine with firmware from V01.10

Applications
Holding of a load while the QSP function is activated.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201109720/1/