Corrections when writing the DRIVECOM index 0x6004

Eliminated from:
EMF 2133 IB communication module Firmware 2.1

Behaviour of the new version?
By means of firmware 2.1 DRIVECOM index 0x6004 can be written without problems.



Which products are affected?
EMF 2133 IB communication module Firmware 2.0

What happens?
The write request to index 0x6004 is rejected. As a result, it is not possible to set a response on the Profibus if the communication is interrupted.

When does the problem occur?
If, in case of a communication interruption, a response is to be set on the Profibus via DRIVECOM index 0x6004 .

Possible diagnostics?
The write request to index 0x6004 is rejected.

Short-term measures/recommendations?
In case that the communication is interrupted, a corresponding response can also be set via Lenze code L-C1882.

Evaluation:
None.