Software limit position recognition - software limit position approached

Function extension
The information that software limit positions have been approached can now be seen from MCK status bits 14 and 15.

Included in which versions/products?
8400 HighLine with firmware version 05.01 or higher

Applications
Limitation of the traversing range in the respective operating modes and evaluation by means of a control.

Information taken from chapter 2.1.2 of Service Message No. 16/2010.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201005119/1/