Error when transmitting the codes of the Inverter Drive 8400 (remedied from V4.5)

Eliminated from:
L-force Loader V4.5

Behaviour of the new version?
The L-force Loader V4.5 transmits codes of the Inverter Drive without any rounding errors.




What is the reaction?
- During the transfer of the codes into the Inverter Drive 8400, errors occur. These codes are displayed in a note dialog at the end of the download.
- If the value transferred to a code has more than 6 digits, rounding errors may occur.

When does the problem occur?
When a code is written with the INTEGER_32 data type and the factor 1 (=no decimal positions), the functional restriction may occur.

Which products are affected?
L-force Loader V4.4
Inverter Drive 8400

Diagnostics options?
None

Short-term measures/recommendations?
Use the L-force Loader V4.5. for download.

Evaluation
The functional restriction may cause rounding errors and errors during the transfer of code values to an Inverter Drive 8400. This function restriction is eliminated with the L-force Loader V4.5.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201002742/1/
Kontaktformular