V/f characteristic control with 11 interpolation points that can be set (from V4.0 onwards)
Function extension:
The operating mode 'V/f characteristic control definable' (L-C00006 = 10) makes it possible to set any characteristic by means of 11 interpolation points. The interpolation points (voltage/frequency values) of this characteristic are stipulated by means of the 11 subcodes of L-C00967 and L-C00968.
Applications
Operation of reluctance or synchronous motors during controlled acceleration (reduction of natural oscillation due to incorrect excitation) as well as adaptation of the voltage requirement for the motor, depending on special load conditions.
In which products/versions is it included?
8400 StateLine SW V4.00 onwards
8400 HighLine SW V4.00 onwards