Lenze setting for linking signals of the torque limits changed (from V2.2)

Which products are affected?
8400 BaseLine D (as of Firmware V2.2)

Function description
The selection of torque limits in motor and generator mode have now been combined and preconfigured in one parameter in the Lenze setting.
As a result, there is one freely adjustable value available for the limitation in motor and generator mode due to the adjustment of the Lenze default setting. Therefore, the BaseLine behaves consistently to the other devices of the 8400 family.

Parameter, which have been prepared as torque limit in the Lenze default setting:
  • NPar3_a = C0472/3 as torque limit in motor and generator mode (LA_NCtrl_nTorqueMotLim_a) preassigned with 100 %
  • NPar4_a = C0472/4, not used

A distribution on two different parameters can be implemented by a corresponding configuration.

Compatibility with lower firmware versions is granted.

Applications
Limitation of the torque in motor or generator mode

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200907172/1/