Motor phase failure detection is not triggered at standstill (remedied from V5.0)

Remedied from?
9400 HighLine SW V5.0
not eleiminated in 9400 StateLine SW ≤ V4.0

Eliminated function restriction
If a response is set in code C00597 (response to motor phase failure) which is unequal to C00597= 0 (no response), motor phase failure detection is carried out in the controller. So far the monitoring has not been triggered at a standstill.
Now the motor phase failure detection has been revised to also detect failures if the motor is at a standstill. This function is very helpful in the case of drives that are equipped with brakes: The braked motor can be checked for motor phase failure first before the brake is released.

Published with Service Message No. 18/2009