Table positioning - Profile data display does not indicate the new target position after Teach position (remedied from V2.0 onwards)

Remedied from:
8400 HighLine   SW V2.00 onwards

Behaviour of the new version?
The above-named software version rectifies this functional restriction.




Which products are affected?
8400 HighLine   SW ≤ V1.00

What happens?
A wrong value for the target position is indicated in the positioning profile if the 'Teach position' function is used at the Motion Control Kernel' in order to enter a position target, which has been defined externally via process data, into a positioning profile selected.

When does the problem occur?
The problem occurs in the 'Table positioning' application if the 'Teach position' function is used to select externally via process data a new target position for a positioning profile. After 'teaching' the position (L-C01301/1..15) the original value is displayed although the 'teached' position is active in the background.

Possible diagnostics?
Compare the target position in the corresponding profile set (L-C01301/1..15) before and after teaching.

Short-term measures/recommendations?
None.

Evaluation:
This function restriction only affects displayed values. The 'mechanical' position of the drive is correct.

Published with service message No. 2009/02

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200902753/1/