Table positioning - rounding error in actual value displays (eliminated from V5.0 onwards)
Eliminated from:
HighLine with firmware version V05.01 or higher
Behaviour of the new version?
This function restriction is eliminated with the above-mentioned firmware version.
Which products are affected?
8400 HighLine with FW < 05.01
What happens
The parameters for displaying the actual position (e. g. C01210/3 and 4) of the 'Table positioning' application have a rounding error and do not display any decimal positions. However, the error does not affect the actual 'mechanical' position of the drive, it just accounts for incorrect display values.
When does the problem occur?
In the 'Table positioning' application, the problem is evident in all display parameters for actual positions.
Possible diagnostics?
Comparison of display value and actual position
Short-term measures / recommendations?
None
Evaluation:
This function restriction only affects the display values. The 'mechanical' position of the drive is correct.