TP positioning, following a profile abort by ProfEnable=0 TP, positioning is still performed (remedied from V2.0 onwards)

Remedied from:
ECS Posi&Shaft V2.0 onwards

Behaviour of the new version ?
After ProfEnable=0 aborts a profile with TP positioning, the TP input no longer responds nor stops correctly during the deceleration ramp.




What happens?
After ProfEnable=0 aborts a profile with TP positioning, upon detection of a TP signal, TP positioning continues and the residual path is executed.

When does the problem occur?
If a TP signal continues during the stop ramp after ProfEnable=0 has aborted a profile with TP positioning.

Which products/versions are affected ?
ECS Posi&Shaft <= V1.3

Possible diagnostics?
None..

Short-term measures/recommendations?
Ensure that a TP signal does not occur during the stop ramp. If necessary, activate quick stop (QSP) as a precaution.
In certain circumstances, the impact can be reduced by dividing the residual path of the TP positioning to be executed into a short residual path of the TP positioning and a subsequent relative positioning.  

Evaluation:
In application cases where an unexpectedly longer braking distance could pose a risk, QSP must also be activated.

Published with service message No. 2009/13