Code C13078 or C14078 cannot be accessed (remedied from V1.05)

Remedied from:
Communication module E94AYCEP Firmware V1.05

Behaviour of the new version
The code C13078 and C14078 can be accessed without problems.



Which products are affected?
Communication module E94AYCEP Firmware V0.51

What happens?
The code cannot be changed / written.

When does the problem occur?
If the default setting (5 s) of code C13078 / C14078 (max. time for detecting an EPL master) is to be changed.

Possible diagnostics?
Written values are not accepted permanently. After reset node or mains switching the default value of 5 seconds is again indicated under code C13078 / C14078.

Short-term measures/recommendations?
None.

Evaluation:
In firmware version 1.05, code C1x078 can be accessed without problems.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200807366/1/
Kontaktformular