Hiperface absolute value encoder, modification of the number of pulses per revolution under C0420 does not always lead to SD7 Trip with re-initialisation of the rotor position as a consequence
Which products are affected?
9300ES servo controller V7.0
9300EP position controllers as of V8.0
Eliminated function restriction
The modified number of pulses per revolution under C0420 now always leads to a SD7 Trip in order to cause mains switching for the required re-initialisation of the actual position and the rotor position.