Rounding deviations when code C0222 (Vp process controller PCTRL) is read out via fieldbus (remedied from V7.0)

Which products are affected?
9300EP position controller V7.0
9300ES servo controller V7.0

Eliminated function restriction
If code C0222 (Vp process controller PCTRL) is read out via a fieldbus the value indicated has up to now been rounded inexactly as of the second decimal place.
Example: Code value 0.1 => but 0.094 was read out via fieldbus.
Now, the value is transmitted with two correctly rounded decimal places.



Which products are affected?
9300EP position controller <= V6.2
9300ES servo controller <= V6.2

What happens?
If code C0222 (Vp process controller PCTRL) is read out via a fieldbus the value indicated is rounded inexactly as of the second decimal place.
Example: Code value 0.1 => but 0.094 is read out via fieldbus.

When does the problem occur?
The problem only occurs if the code is read out via fieldbus since the fieldbus asks for and indicates four decimal places although only two are available.

Possible diagnostics?
Compare the value of code C0222 read out via fieldbus with the one read out via keypad.

Short-term measures/recommendations?
None.

Evaluation:
Minor consequences.