CALC command calls up the POU irrespective of the condition (elimination)

Which products are affected?
ESP-DDS2-x (Drive PLC Developer Studio V2.3 SP2)

Function description
In the instruction list (IL) programming language the instance of a function block is only called up by means of the CALC command if the result of the preceding expression is TRUE.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200601039/1/