Evaluation of the last scan value at the function block L_CamSetXAxisVelocity (elimination)

Which products are affected?
ESP-SPAC-CAM1 — Software Package Cam V1.5 (LenzeCamControl1V0105.lib library)

Eliminated function restriction
In the revised function block the last scan values are evaluated with the correct sign at the function block input L_CamSetXAxisVelocity.dnTpIncLastScan_p if the master value (L_CamSetXAxisVelocity.bCwCcw = TRUE) is inverted and the touch probe correction function is activated. As a result, inaccuracies in the position correction of the master value and the process are avoided.
Due to a function restriction in the Software Package Cam V1.4 (LenzeCamControl1V0104.lib library) this was not possible. Thus the function block input L_CamSetXAxisVelocity.dnTpIncLastScan_p was evaluated with the wrong sign.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200508262/1/