Remedied from?
GDC 4.8, GDC 4.8 update or GDC 4.8 easy in combination with the starttec motor starter firmware version ≥ 2.x
Behaviour of the new version?
The inputs and outputs visualised on the AS-i monitor are indicated correctly as of starttec firmware version ≥ 2.x.
Which products are affected?
GDC 4.7, GDC 4.7 Update or GDC 4.7 easy in combination with a starttec motor starter firmware version < 2.x
What happens?
The inputs and outputs visualised on the AS-i monitor are not indicated correctly, i. e. the level is partially inverted. The actual data communication is working correctly.
When does the problem occur?
The problem can only be seen in the visualisation mode.
Possible diagnostics?
The visualisation can be checked by calling up the AS-i monitor window.
Short-term measures/recommendations?
The information are indicated correctly in the AS-i monitor dialog as of starttec firmware version ≥2.x.
Evaluation:
Due to the incorrectly indicated inputs and outputs, the values indicated may be misinterpreted.