Error message ¨Not a valid page (0)¨ when sequences are created

Which products are affected?
ESP-HMI1-P (HMI Designer Version 1.2 and higher)

EPM-H310 (text display)
EPM-H315 (text display)
EPM-H410 (graphical display)

What happens?
A sequence determines which pages are linked so that they can be passed through by means of the arrow keys. A new sequence is created by means of the Sequences project component.

When the page numbers for the definition of a sequence are entered the following error message occurs:
Not a valid page (0)

When does the problem occur?
The page number defining a sequence can be selected in the corresponding dialog boxes (e. g. Start page field) by means of a selection list. In the field a term like: Page No. 0001 will be indicated.
Alternatively to the selection list the page number can be entered in these fields directly as numeric value.

If, however, the term in the field is edited, e. g. Page No. 0002 is written in the field instead of Page No. 0001 the following error message will appear:
Not a valid page (0)

This function restriction affects the text displays H310 and H315, as well as the graphical display H410.

Possible diagnostics?
None.

Short-term measures / recommendations?
In order to define a sequence, select the page number from the selection list.

Evaluation:
An error message is displayed when the pages are defined for a sequence. This function restriction can be avoided when the selection list is used for selecting the page numbers. Touch screens are not affected by this function restriction.