Task overrun caused by impermissible current controller values (remedied from B-SW V6.6)

Remedied from:
ECS axis module B-SW  V6.6

Behaviour of new version?
A task overrun or float error does not occur any longer when entering too high current gain factors.



Which products are affected?
ECS axis module B-SW ≤ V6.5

What happens?
Task overrun.

When does the problem occur?
When entering current gain factors larger than the limit values indicated in the documentation.

Possible diagnostics?
Indication on the display of the operating unit or in GDC.

Short-term measures/recommendations?
None.

Evaluation:
This problem only occurs during commissioning and can be eliminated by mains connection.

Published with service message No. 2004/44 and 2004/45