8200 vector/motec: Controller inhibit during parameter set transfer (remedied from V4.7)

Remedied from?
GDC 4.7 and GDC easy 4.7

Behaviour of the new version?
Parameter sets can only be transferred if the controller is inhibited.



Which products are affected?
GDC 4.6.1 and GDC easy 4.5

What happens?
The parameter set can also be transferred if the controller is not inhibited since the information for enabling the parameter set transfer has been taken from code C0135 so far.

When does the problem occur?
The problem occurs when parameter sets are transferred.

Possible diagnostics?
If parameter sets can be transferred when the controller is not inhibited, this may indicate the error described above.

Short-term measures/recommendations?
In order to ensure a safe status of the drive during the parameter set transfer, the software controller inhibit (GDC Stop Button) or hardware controller inhibit (terminal 28) can be used.
The error has been eliminated in GDC 4.7 and GDC easy 4.7.