Parameter set download via GDC into PLC not possible (elimination)

Which products are affected?
EVS93xx-EI (Servo PLC, software version 6.1)
EVS93xx-ET (Servo PLC, software version 6.1)
EPL 10200 (Drive PLC, software version 6.1)

Function restriction corrected
It is possible to write on code C1215 (Touch Probe functionality) via GDC without any restriction.
 
Which products are affected?
EVS93xx-EI (Servo PLC, software version 6.0)
EVS93xx-ET (Servo PLC, software version 6.0)
EPL 10200 (Drive PLC, software version 6.0)

What happens?
Code C1215 cannot be written via GDC if the parameter set is downloaded.

When does the problem occur?
If the touch probe functionality is not integrated under DDS because it is not required in the project, writing on code C1215 will not be allowed.

Possible diagnostics?
None.

Short-term measures/recommendations?
None.

Evaluation:
The operating system 6.0 is still a field test version. The error will be eliminated in the series release version.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200408618/1/