Charging of the DC bus improved (V2.3 onwards)

Which products are affected?
Supply module ECSxE series, operating software V2.3

Function description
The behaviour when charging the DC bus after mains connection has been improved in order to avoid an abortion of the charging process with the corresponding error messages in case of larger DC bus capacities and non-rigid mains conditions.
Moreover, the control of the charging mains current (effective value) to the maximum value set under C0022 has been improved.
The determination of the comparison criterion to stop the charging process has been improved, too.

Applications
Mains connection of the ECS servo system.