Latching the input of the minimum and maximum output frequency (elimination)

Which products are affected?

8200vector 0.25 - 90 kW (≥ SW 3.5) with standard I/O or application I/O (≥ SW 3.5)
8200motec 0.25 - 7.5 kW (≥ SW 3.5) with standard I/O or application I/O (≥ SW 3.5)

Eliminated function restrictions:

Entering a value for the minimum output frequency (C0010) which was higher than the value for the maximum output frequency (C0011) could lead to an undesired change of direction of rotation in the case of an analog setpoint selection of 0 V and different acceleration and deceleration times. A uncontrolled change of diretion of rotation can now be excluded.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200406521/1/
Kontaktformular