Communication monitoring

Which products are affected?
All starttec versions as of version HW VC, SW 1.3.

Function description:
Code C0126 has been created for monitoring the communication between basic device and FIF module (Response in the event of a communication error).
So far, the starttec did not provide any monitoring of the communication between basic device and FIF module.
Due to the modification, the starttec has been adapted to the 8200 vector functionality. If the communication between basic device and FIF module is interrupted, a corresponding response can be parameterised (see table).
C0126 can be programmed by using the keypad or with GDC ≥ 4.7.

Applications:
Monitoring of the communication between an optional fieldbus function module and the starttec. If the communication is interrupted, a Trip message is indicated.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200406217/1/