Drive sporadically indicates an LU message

Which products are affected?
EVS93xx-EI (Servo PLC Version 6.3 DSMC control board)
EVS93xx-ET (Servo PLC Version 6.3 DSMC control board)

What happens?
The drive indicates a LU message. The power outputs are switched to high resistance level – the drive coasts down.

When does the problem occur?
The problem occurs if a series of conditions is complied with at the same time:
  • Devices with power < 9325 AND
  • C0022 AND C0086 included in the code initialisation list of the project AND
  • C0022 > 1.5 x Irated device.

The problem occurs sporadically. Mostly after a project download and after 'Mains on' but also sporadically during operation.

Possible diagnostics?
None.

Short-term measures/recommendations?
The LU message can be acknowledged by mains switching.

Evaluation:
The error will be eliminated in a higher version of the operating system.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200406087/1/