Which products are affected?
Positioner Software Package –V3.3
LenzeMotionControlV3.lib
Eliminated function restriction
If the overchange function is active and the profile position is not plausible the status nState = -300 is output and the set deceleration ramp is used to decelerate to velocity v = 0. The status means: 'Positioning with the selected profile is not plausible. The traverse path to the selected position is shorter than an integration step of the profile generator'.