Which products are affected?
9300 Servo cam, version 3.4
Eliminated function restriction
The calculation for filtering / delay of a master frequency signal vi a the filter was corrected.
Oscillations on a digital frequency signal can be filtered by using master frequency signal without using the position reference. The increments to be output delayed are saved internally.
Attention:
The internal memory can store a position difference up to 2147483647 (2^31 - 1) increments.After this difference was exceeded there will be a loss of the defined position (position overrun). In this case the function block is to be reset via the input PT1-2-RESET.