TP positioning and Prg-Stop (elimination)

Which products are affected?

Function restriction on the 9300EP servo positioning controller as of versions V2.5 and V6.1.

Eliminated function restriction

If Touch Probe positioning has been interrupted by Prg-Stop, the TP was no longer initialised properly after continuation of TP positioning (Prg-Stop = Low) so it was not evaluated either.
Now TP positioning is also executed properly after Prg-Stop.

Possible diagnostics?

Interrupt TP positioning before the occurrence of TP by Prg-Stop. Then check whether there is a response to the TP.

Short-term measures/recommendations?

After Prg-Stop also perform a program reset in order to restart TP positioning again.

Evaluation:

The phenomenon only occurs if stopping is performed by Prg-Stop anyway so a program reset will be acceptable here. If not, change the firmware by means of a download.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20035228/1/