Indication with writing and reading jobs when using fieldbus modules

Difference description 2175IB SW V0.8 to V0.9

1. Product identification
  • article number new (V0.9): 421049
  • construction labelling new: 2175IB.VB.09 or 2175IB.VC.09
  • ordering designation: EMF2175IB
  • article number old (V0.8): 403940 or 416657

2. Function improvements

Application
Writing and reading jobs are carried out with the communication profile CanOpen.

Description
During the operation of 8200 vector with the function modules Profibus-DP, Interbus or LECOM-B fault indications (not specified according to CanOpen) will occur if writing or reading jobs are activated via fieldbus module type 2175 V0.8 to the function module.

Elimination
With software version V0.9 these unspecified fault indications will not occur any more if Profibus-, Interbus or LECOM-B function modules are used.

Short-term measure in the previous version
None

Possible diagnostics
Fault indications are sent back in the constellation mentioned above. These messages are not documented.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20011202/1/