Rounding errors at the transmission of values in codes

The following products are concerned:
EPL-10200 (Drive PLC software version 1.3)
EVS9300-Ex (Servo PLC software version 1.3)

Reactions to the problem:
The values transmitted in codes are rounded by the Drive PLC/Servo PLC. If the value is read out of the code again, this value does not correspond with the former transmitted value.
If, for example, the value 80,00 is transmitted in the code C0039/1 (JOG set value), this value is rounded to 79,99 in the control.

When does the problem occur?
The reason for this problem is the control-internal standardisation of certain codes. Describing the codes, a standardisation and thus a rounding of the value takes place.

Diagnosis possibilities:
The rounded value can be read out of the code e. g. with the GDC program or the PLC function block L_ParRead.

Short-term measures/recommendations:
none

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20010052/1/