Corrected from:
Library: L_TS2P_TechModulesSynchronizingCamming (from V3.25.0)
(Update via Easy Package Manager)
Response of the new version:
The parameter lrSyncOutDist for the eSyncMode = RampDist is always used for the disengagement!
What happens?
When coupling out conductance with xSyncPos = FALSE, the parameter lrSyncInDist and not lrSyncOutDist is used.
When does the behaviour occur?
The coupling mode is set to eSyncMode = RampDist.
The base speed function lrSetBaseVel > 0 is activated.
The coupling is opened with xSyncPos = FALSE.
Which products are affected?
L_TS2P_SyncAndCorrectionBase from library L_TS2PTechMoulesSynchronizingCamming
Short-term measures:
The parameters lrSyncInDist and lrSyncOutDist must be set to the same value.
Evaluation / recommendations:
The disengagement to the basic speed should always be used via the parameter lrSyncOutDist for the mode eSyncMode = RampDist. Even if the basic speed is greater than the speed of the master value.