L_MC1P: MC_TouchProbe TouchProbeSource = 4 (touch probe from external encoder axis) does not work as expected (fixed from V03.32.00)

Removed from:
Library:  L_MC1P_MotionControlBasic  (FAST Motion)   as of V03.32.00
Behavior of the new version:
It is now also possible to capture a TP position if the TouchProbe event comes as a trigger from a different motion axis.



Description of behavior:
MC_Touchprobe: It s not possible to use the touchprobe event of another motion axis as the TouchProbe source.
The error message "NoValidTpSource" (20314/0x4F5A) is displayed on the MC_Touchprobe.

Conditions under which the behavior occurs:

  • MC_Touchprobe: Motion axis (axis A) is connected to the Axis input and
  • under MC_Trigger_Ref is selected as TouchProbeSource mode 4 (external motion axis).
  • MC_Trigger_Ref.ExternalTPFromAxis is assigned a 2nd motion axis (axis B).

Affected products:
Library:  L_MC1P_MotionControlBasic  (FAST Motion)

Short-term measures, Recommendations, Rating: